1. Virtual Connect의 시간 설정은 단독으로 하지 않고, Onboard Administrator에서 설정한다.
2. OA에서 시간을 설정해도, 즉각적으로 VC에 적용되지 않고 동기화 되는데, 수 분의 시간이 필요하다.(약 10분)
참고자료.
How to set the date and time on Virtual Connect?
http://h30499.www3.hp.com/t5/HP-BladeSystem-Virtual-Connect/How-to-set-the-date-and-time-on-Virtual-Connect/td-p/6246847#.VEjfHukcSUl
If you update the time/date on the OA, it will not immediately be reflected in the VC Logs.
The OA will update ISMIC information on the VC modules on an Interval.
Every 600 seconds VC request this.
OA will update the ISMIC Block, the VC modules will read that ISMIC Block and set the Date/Time on the Modules in Kernel.
VC Logs will use the Date/Time of the Kernel.
It would likely take a few intervals for time/date to stabilize and completely sync between OA/VC.
But again customers shouldn’t be changing the date/time very often if at all once system is running.