Upgrade Virtual Connect firmware with Manual/Serial Option

by 스쳐가는인연 2015. 1. 30.

Healthcheck


CLI> vcsu –a healthcheck –I 10.254.4.157 –u Administrator –p Password –vcu Administrator –vcp Password

CLI> vcsu -a healthcheck -i <Active OA IP Address> -u <OA Account> -p <OA pwd> -vcu <VC Account> -vcp <VC pwd>

** check In Sync Status


VCM System Log--------------

2015-01-29T04:17:43+00:00 VC vcmd: [VCD:ENC_vc_domain:1010:Info] VCM user login : Administrator@10.154.248.84

---------------------------

 

Execute command for fw up to v4.31


CLI> vcsu –a update –I 10.254.4.157 –u Administrator –p Password –vcu Administrator –vcp Password –oe manual –l C:\Users\Administrator\Downloads\vcfwall431.bin

 

--------------------------------------------------------

Would you like to continue with this update? [YES/No]: YES

--------------------------------------------------------


VCM System Log--------------

2015-01-29T04:27:12+00:00 VC vcmd: [VCD:ENC_vc_domain:1001:Info] VCM initialized

---------------------------


Progress on vcsu - Starting > Updating > Activating

Can't connect to VCM during update progress, If try to standby, redirect to primary

 

Progress on vcsu - Starting > Updating > Activating

Can connect to VCM after activating fw progress at least more than 10%

“Enclosure import completed : Name [C7000M17U12]” logged on System log of VCM


VCM System Log--------------

2015-01-29T04:27:59+00:00 VC vcmd: [ENC:SN:2002:Info] Enclosure import completed : Name [ENC]

2015-01-29T04:27:59+00:00 VC vcmd: [VCD:VCM:1035:Info] Build Information : 4.20-323

---------------------------

 

“VCM Domain checkpointed” logged on System log of VCM

And vcsu task ended at same time


VCM System Log--------------

2015-01-29T04:29:19+00:00 VC vcmd: [VCD:ENC_vc_domain:1004:Info] VCM Domain checkpointed

---------------------------

 

Role check via About VCM menu


Reset standby(iobay #2) via OA’s Interconnect Bays – Virtual Buttons


VCM System Log--------------

2015-01-29T04:35:35+00:00 VC vcmd: [ENET:enc0:iobay2:3001:Info] Enet Module reset

--------------------------- 


“VCM Domain checkpointed” logged on System log of VCM


VCM System Log--------------

2015-01-29T04:39:28+00:00 VC vcmd: [VCD:ENC_vc_domain:1004:Info] VCM Domain checkpointed

--------------------------- 

 

Reset VCM with select checkbox of Force Failover for take over VCM between iobay #1 and iobay #2.


VCM System Log--------------

2015-01-29T04:42:27+00:00 VC vcmd: [VCD:ENC_vc_domain:1034:Info] User Operation : Reset VCM (Administrator@10.154.248.84)

2015-01-29T04:43:06+00:00 VC vcmd: [VCD:ENC_vc_domain:1001:Info] VCM initialized

2015-01-29T04:44:12+00:00 VC vcmd: [ENC:SN:2002:Info] Enclosure import completed : Name [ENC]

2015-01-29T04:44:12+00:00 VC vcmd: [VCD:VCM:1035:Info] Build Information : 4.31-5

--------------------------- 

 

Can't connect to VCM during take over progress

 

“VCM Domain checkpointed” logged on System log of VCM

Can connect after complete take over.


VCM System Log--------------

2015-01-29T04:45:38+00:00 VC vcmd: [VCD:ENC_vc_domain:1004:Info] VCM Domain checkpointed

--------------------------- 

 

Reset standby(iobay #1) via OA’s Interconnect Bays – Virtual Buttons


VCM System Log--------------

2015-01-29T04:47:55+00:00 VC vcmd: [ENET:enc0:iobay1:3001:Info] Enet Module reset

---------------------------  

 

“VCM Domain checkpointed” logged on System log of VCM


VCM System Log--------------

2015-01-29T04:52:01+00:00 VC vcmd: [VCD:ENC_vc_domain:1004:Info] VCM Domain checkpointed

---------------------------  

 

VC fw Rollback to v4.20 (if needed)

CLI> vcsu –a update –I 10.254.4.157 –u Administrator –p Password –vcu Administrator –vcp Password –oe serial –l C:\Users\Administrator\Downloads\vcfwall420.bin

 

Progress on vcsu - Starting > Updating > Activating

Can connect to VCM after activating fw progress at least more than 10%


VCM System Log--------------

2015-01-29T04:17:43+00:00 VC vcmd: [VCD:ENC_vc_domain:1010:Info] VCM user login : Administrator@10.154.248.84

2015-01-29T05:17:49+00:00 VC vcmd: [VCD:ENC_vc_domain:1001:Info] VCM initialized

2015-01-29T05:19:54+00:00 VC vcmd: [ENC:SN:2002:Info] Enclosure import completed : Name [ENC]

2015-01-29T05:19:54+00:00 VC vcmd: [VCD:VCM:1035:Info] Build Information : 4.20-323

2015-01-29T05:21:42+00:00 VC vcmd: [VCD:ENC_vc_domain:1004:Info] VCM Domain checkpointed

---------------------------  


** VC fw를 상위 버전으로 업그레이드 하는 경우 기존 fw 버전의 로그가 유지되나, 하위 버전으로 Rollback(Downgrade) 하는 경우 기존 fw 버전의 로그가 삭제된다.