'2019/06/09'에 해당되는 글 2건

  1. 2019.06.09 SmartArray - SSA - How monitor rebuild progress
  2. 2019.06.09 MegaRAID - How monitor rebuild progress

---------------------------------------
# Location VMware ESXi 4.0/4.1/5.0
/opt/hp/hpacucli/bin/hpacucli

# Location VMware ESXi 5.1/5.5/6.0
/opt/hp/hpssacli/bin/hpssacli

# Location VMware ESXi 6.5/6.7
/opt/smartstorageadmin/ssacli/bin/ssacli
---------------------------------------

Get Slot Information - Slot x
# ./ssacli ctrl all show status

Check Rebuild progress
# ./ssacli ctrl slot=XX ld all show

or
# ./ssacli ctrl slot=XX show config

출처:
HOWTO: Monitor the rebuild status of a HPE SmartArray in ESXi 5.5
http://blog.jbgeek.net/2016/04/14/howto-monitor-the-rebuild-status-of-a-hpe-smartarray-in-esxi-5-5/

HPE Storage Controller Management (ssacli)
https://be-virtual.net/hpe-storage-controller-management-ssacli/

Posted by 스쳐가는인연

/opt/lsi/MegaCLI # ./MegaCli -PDRbld -ShowProg -PhysDrv [:1] -a0

Rebuild Progress on Device at Enclosure N/A, Slot 1 Completed 7% in 170 Minutes.

Exit Code: 0x00
/opt/lsi/MegaCLI #

 

server:~# megacli -PDRbld -ShowProg -PhysDrv [32:1] -aALL

Rebuild Progress on Device at Enclosure 32, Slot 1 Completed 51% in 10 Minutes.

출처:
https://hwraid.le-vert.net/wiki/LSIMegaRAIDSAS
https://communities.vmware.com/thread/530391

Posted by 스쳐가는인연